فیلترها/جستجو در نتایج    

فیلترها

سال

بانک‌ها



گروه تخصصی











متن کامل


اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    9
  • شماره: 

    6
  • صفحات: 

    665-676
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    65
  • دانلود: 

    0
چکیده: 

Background: Pelvic fracture is one of the most common fractures in the elderly, especially in the intertrochanteric region. Therefore, in the present study, an external fixator was designed specifically for intertrochanteric fractures. The present study aimed to compare the operating time, amount of bleeding, and mortality rate between the patients who received either Dynamic hip external fixators (DHEF) or Dynamic hip screw (DHS). Methods: In 2018, 46 patients with intertrochanteric fracture due to trauma and high anesthesia risk were included in the study and randomly assigned to two groups of control (n=24, patients treated with DHS) and intervention group (n=22, patients treated with the DHEF). Treatment was carried out using the DHEF which was newly designed and placed outside the patient's body under short and light anesthesia. After 3 and 12 months of follow-up, the two groups were compared for some variables, including mortality rate, pain intensity, Harris hip score (HHS), cut-off rate of the device, femoral neck angles before and after the operation, hemoglobin changes, hematocrit levels before and after the operation, the number of injected blood units, and the number of hospitalization days. Results: Mortality rate was higher in open surgery with DHS. The assessment of variables in both intervention and control groups demonstrated that duration of operation (P<0. 001), hospitalization length, time to union (P=0. 001), pain intensity five days after the operation, as well as changes in Hb and HCT, were significantly higher in the control group than the intervention group. The mean HHS scores of 83. 5± 14. 3 and 78. 2± 11. 5 were gained for the DHEF and DHS groups, respectively (P=0. 22). conclusion Considering the superior results of treatment with the external fixator in comparison with the DHS, such as lower mortality rate and fewer complications, a Dynamic hip external fixator can be prescribed in patients with intertrochanteric fractures and high anesthesia risk.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 65

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    0
  • دوره: 

    8
  • شماره: 

    1 (پی در پی 29)
  • صفحات: 

    96-100
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1255
  • دانلود: 

    296
چکیده: 

سابقه و هدف: شکستگی استخوان درشت نی شایعترین شکستگی استخوان های بلند در بدن است که در درمان آن نظرات متفاوتی وجود دارد. یکی از روشهای درمانی، اکسترنال فیکساتور می باشد. این مطالعه به منظور بررسی نتایج درمانی استفاده از اکسترنال فیکساتور در بیماران با شکستگی باز استخوان درشت نی در بابل انجام شد.مواد و روشها: این مطالعه کارآمایی بالینی از نوع نیمه تجربی بر روی 106 بیمار مبتلا به شکستگی باز استخوان درشت نی درمان شده بوسیله اکسترنال فیکساتور در بیمارستانهای بابل طی سالهای 82-1370 انجام شد. پس از بستری بیماران، شستشوی زخم و دبریدمان انجام شد و سپس اکسترنال فیکساتور قرار داده شد. بیماران بطور منظم ویزیت شده و رادیوگرافی سریال جهت کنترل تا یکسال انجام شد. سپس نتایج آنها مورد بررسی قرار گرفت.یافته ها: در این مطالعه 90.5% شکستگی در اثر تصادف ایجاد شده بود. در 98.1% بیماران بطور متوسط پس از 4 ماه شکستگی جوش خورده بود. عفونت مسیر پین در 24% افراد دیده شد که در 2 مورد منجر به استئومیلیت گردید. لق شدن پین ها در 5.7% موارد، آسیب پرونئال دایمی در 4.7% و جوش نخوردن در 1.9% از یبماران مشاهده شد.نتیجه گیری: نتایج مطالعه نشان داد که اکسترنال فیکساتور وسیله ای قابل اطمینان در درمان شکستگی های باز استخوان درشت نی می باشد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1255

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 296 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

دهقانی محمد

اطلاعات دوره: 
  • سال: 

    1387
  • دوره: 

    6
  • شماره: 

    4-الف (مسلسل 25)
  • صفحات: 

    197-202
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    915
  • دانلود: 

    187
چکیده: 

پیش زمینه: شکستگی دیستال رادیوس بسیار شایع است. در مورد درمان شکستگی های ناپایدار هنوز در بین جراحان ارتوپد بحث و جدل وجود دارد و اتفاق نظر دیده نمی شود. استفاده از تثبیت خارجی هیبرید (non-bridging hybrid fixation)، یکی از روش های درمانی است که در این مطالعه نتایج آن مورد بررسی قرار گرفت. مواد و روش ها: در یک مطالعه توصیفی، در 18 بیمار که با شکستگی ناپایدار دیستال رادیوس بین سال های 1386-1383 به یک مرکز درمانی اصفهان مراجعه کردند، از ثابت کننده خارجی هیبرید الیزاروف به مدت 7 هفته استفاده شد. در محل شکستگی، 5-3 پین ظریف به یک نیم حلقه الیزاروف و در پروگزیمال به شانز پین متصل شده بود. پیگیری بیماران در روز اول، یک هفته، 7 هفته و 6 ماه بعد از جراحی انجام شد. یافته ها: در تمام موارد جوش خوردگی مشاهده شد ولی در %90 بیماران (16 مورد) جااندازی آناتومیک به دست آمد. دامنه حرکتی %80 خم شدن مچ دست، %85 بازشدن و %90 سوپیناسیون و پروناسیون نسبت به سمت سالم گزارش شد. هیچ مورد آسیب تاندون اکستانسور، التهاب تاندون و شل شدن پین ملاحظه نشد. در 5 مورد عفونت سطحی اطراف پین دیده شد که با تجویز آنتی بیوتیک خوراکی به مدت 3 روز برطرف گردید. نتیجه گیری: به نظر می رسد این روش در شکستگی های داخل مفصلی دیستال رادیوس روش بی خطر و مطمئن است که همزمان با تثبیت استخوان اجازه حرکت مفصل را می دهد و مانع خشکی مفصل می گردد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 915

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 187 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1395
  • دوره: 

    34
  • شماره: 

    395
  • صفحات: 

    952-957
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    2961
  • دانلود: 

    251
چکیده: 

مقدمه: در شکستگی های اینترتروکانتریک، وسیله ای که بیش از همه مورد استفاده قرار می گیرد، Dynamic hip screw (DHS) می باشد، اما مطالعات متعددی نتایج خوبی از این وسیله در شکستگی های Transverse و Reverse-oblique گزارش نکرده اند. این مطالعه با هدف مقایسه ی نتایج فیکس کردن شکستگی های اینترتروک Reverse-oblique و ساب تروکانتریک Short segment با استفاده از DHS و Dynamic condylar screw (DCS) در بیماران مراجعه کننده به اورژانس ارتوپدی بیمارستان های الزهرا (س) و آیت اله کاشانی اصفهان در سال های 1390 تا 1393 انجام شد.روش ها: طی یک مطالعه ی مقطعی، 50 بیمار مبتلا به شکستگی های اینترتروک Revers-oblique و ساب تروکانتریک Short segment در دو گروه 25 نفره تحت درمان با استفاده از DHS و DCS وارد مطالعه شدند. بیمارانی که حداقل 6 ماه از عمل آن ها گذشته بود، جهت ویزیت و معاینه دعوت شدند و از نظر عوارض عمل جراحی شامل جوش نخوردن و Fail شدن وسیله و همچنین، میزان بهبود شکستگی بررسی شدند؛ این موارد، توسط رادیوگرافی ساده ارزیابی شد. نتایج به دست آمده در دو گروه، مورد مقایسه قرار گرفت.یافته ها: در 6 ماه بعد از عمل، در 56 درصد از گروه DHS و 84 درصد از گروه DCS، جوش خوردگی کامل ایجاد شده و بهبودی گروه DCS به طور معنی داری بیشتر بود (P=0.031). همچنین، در 6 ماه بعد از عمل، وسیله ی به کار رفته در 14 نفر از گروه DHS و 24 نفر از گروه DCS فیکس بود و تفاوت دو گروه معنی دار بود (P=0.001). از دو گروه DHS و DCS، به ترتیب 20 درصد و 44 درصد بهبودی کامل یافتند، اما تفاوت دو گروه معنی دار نبود. بررسی شدت درد در این بیماران نیز نشان داد که شدت درد در بیماران تحت عمل با DCS، کمتر بود؛ به طوری که از این گروه 40 درصد و از گروه DHS، 12 درصد به طور کامل بدون درد بودند (P=0.020).نتیجه گیری: استفاده از DCS نسبت به DHS حداقل از نظر شدت درد، میزان جوش خوردن استخوان و نیز ثابت بودن وسیله، برتری دارد و استفاده از آن توصیه می شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 2961

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 251 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

JAFARI DAVOD | AJVADI ALI

اطلاعات دوره: 
  • سال: 

    2017
  • دوره: 

    4
  • شماره: 

    1
  • صفحات: 

    0-0
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    254
  • دانلود: 

    0
چکیده: 

Background: The value of external fixation in complex hand injuries is well established. Expenses and technical difficulties ofcommercial mini external fixator sets have led to the innovation of handmade external fixators. These fixators are used as versatilefacilities to treat certain hand fractures. Usually, these structures are made by k-wires crossed filled with cement plastic tube. However, these fixators have multiple deficiencies that should be addressed. Objectives: In this study, we described in detail the surgical technique of a handmade concrete like mini external fixator and reportits clinical use and results. Methods: Our handmade external fixator was applied for 52 patients with 56 fractures. Only 5% of the fractures were closed, noncomminutedextra-articular, and the other 51 fractures were more complex injuries. The mean follow up time was 9. 3 months. Atthe end of the follow up, radiologic and functional assessment (DASH: Disability of arm, shoulder and hand and TAM: Total activemotion) was evaluated. Results: All 56 fractures were united completely. None of the cases experienced pin loosening or reduction loss. Of the fractures, 8. 9% malunited due to fracture complexity. The mean dash score was 3. 76. TAM was excellent in 45% of the fractures; it was good in7% and fair in 4%. Conclusions: This type of handmade external fixator is simple, lightweight, and cheap. Furthermore, all implements are readilyavailable in most operating fields. The probability of loosening has been greatly diminished because of the concrete like structure. Easy and fast assembly and good clinical and functional results are the other advantages of this technique. Due to the less complicationand benefits, this technique could be used for many phalangeal and metacarpal fractures with confidence.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 254

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    9
  • شماره: 

    6
  • صفحات: 

    695-701
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    89
  • دانلود: 

    0
چکیده: 

Background: Fracture-dislocations of the proximal interphalangeal joint of fingers are believed to be challenging injuries that usually lead to residual pain and stiffness. To date, several treatment options have been applied. Dynamic traction-external fixation is a safe and easy technique offering good results in many works of literature. The Dynamic mini external fixator using K-wires and mini rods provide sufficient Dynamic traction and facilitate early mobilization of the injured joint. The pr esent study was conducted to evaluate the results of a Dynamic mini external fixator for the treatment of those lesions. Methods: In total, 40 patients who suffered from proximal interphalangeal fracture-dislocations were treated at our institution between November 2017 and November 2019. Dynamic mini external fixator device was utilized for their treatment. Clinical and radiographic parameters were evaluated at 2, 4, 6, 12, and 24 weeks after surgery. Results: This study included 30 (75%) males and 10 (25%) females with a mean age of 38. 7± 9. 9 years. In total, 6 (15%) patients had concomitant fractures or fractures in their hands. All the fractures, including 27 (67. 5%) dorsal fracture-dislocations and 13 (32. 5%) Pilon fractures, were united without the occurrence of any malunion or major residual subluxation. One Pilon fracture needed to be realigned by reassembling the device at the second week of follow-up. Furthermore, 36 (90%) patients achieved full range of joint motion, and 4 (10%) patients had mild loss of motion arc. In addition, 8 (20%) patients developed mild pin site infection treated with oral antibiotics without device removal. Following six months, one (2. 5%) patient mentioned minimal residual pain. Conclusion: The Dynamic mini external fixator was found to be a safe and applicable technique to manage proximal interphalangeal fracture-dislocations. To obtain significantly accurate results, regular follow-up and accurate device care are of great necessity.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 89

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1380
  • دوره: 

    1
  • شماره: 

    1 (مسلسل 1)
  • صفحات: 

    44-48
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1087
  • دانلود: 

    173
کلیدواژه: 
چکیده: 

سابقه و هدف: با توجه به شیوع شکستگی های دیستال رادیوس و مشکلات و عوارض روش های درمانی معمول و به منظور تعیین تاثیر و عوارض زودرس این روش، تحقیق بر روی بیماران مراجعه کننده به بیمارستان حضرت رسول (ص) در سال های 1380-1381 انجام گرفت.مواد و روشها: تحقیق به روش کارآزمایی بالینی مقایسه قبل و بعد از درمان بر روی 22 بیمار با شکستگی دیستال رادیوس که با جا اندازی بسته و فیکساتور خارجی مچ از نوع AO تحت درمان قرار گرفته بودند، صورت پذیرفت. تمامی بیماران بعد از اتمام دوره فیزیوتراپی اولیه به مدت حداقل 4.5 ماه پی گیری و ارزیابی شدند. نتایج درمانی با ارزیابی یافته های پرتونگاری و بالینی شامل ارتفاع رادیوس، زاویه و لارواولنار، میزان نامنظم بودن سطح مفصلی، میزان و زمان جوش خوردگی ها با سیستمSarmiento  بررسی گردید.یافته ها: نتیجه عالی در 54.5 درصد بیماران، خوب در 27.7 درصد بیماران و ضعیف در 18.3 درصد بیماران مشاهده شد. حرکات مچ و چرخش ساعد به طور متوسط 90 درصد طرف طبیعی بود. نتایج پرتوشناسی اولیه در 16 بیمار (72.2 درصد) عالی  5 مورد (22.7 درصد) خوب و 1 مورد (4.5 درصد) بد بود. ارتفاع رادیوس در 77.2 درصد بیماران به خوبی حفظ شده بود و در 22.7 درصد بیشتر از 1 میلی متر کاهش ارتفاع وجود داشت. عوارض شامل 2 مورد (9 درصد) عفونت ساده محل پین که با آنتی بیوتیک خوراکی درمان گردید،  1مورد به هم خوردگی جااندازی شکستگی که با تغییر روش درمانی درمان شد. 2 مورد (9درصد) کاهش حرکات انگشت اشاره و 3 مورد (13.6 درصد) Reflex Sympathic Dystrophy  خفیف 1 مورد (4.4 درصد) درد مفصل دیستال رادیواولنارو 1 مورد (4.4 درصد) هایپوستزی ناحیه حسی رادیال وجود داشت. نتیجه گیری و توصیه: به نظر می رسد که این روش نتایج درمانی قابل قبول و عوارض کمتری داشته باشد. این روش در درمان شکستگی های ناپایدار دیستال رادیوس توصیه می گردد. با این وجود انجام یک تحقیق تجربی کامل پیشنهاد می شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1087

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 173 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1383
  • دوره: 

    7
  • شماره: 

    1 (پیاپی 26)
  • صفحات: 

    8-14
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    932
  • دانلود: 

    176
چکیده: 

مقدمه : شکستگی انتهای رادیوس یکی از شکستگی های شایع اندام فوقانی است که درمان آن مورد بحث و اختلاف نظر است و درمان نامناسب می تواند عوارض قابل توجهی به دنبال داشته باشد. در این مطالعه قصد داریم نتایج درمان با روش ثابت کننده خارجی را بررسی نماییم. روش کار: مطالعه به صورت بدون شاهد و نمونه گیری به روش آسان بود. این بررسی  به مدت یکسال روی 30 شکستگی (26 بیمار) انجام شد که براساس رادیوگرافی محل شکستگی نوع 4 یونیورسال5 بودند. عمل جراحی با تکنیک استاندارد با بیهوشی عمومی یا منطقه ای انجام و بیماران تا یکسال پس از عمل جراحی پیگیری و از نظر میزان کوتاهی، زاویه سطح مفصلی و دامنه حرکتی و وجود درد مورد بررسی قرار گرفتند. نتایج: 24  مرد و 2 زن با میانگین سنی 5±28 سال مورد بررسی قرار گرفتند. در همه بیماران جوش خوردن به طور بالینی و رادیوگرافی حاصل شد. 2 مورد عفونت خفیف محل پین وجود داشت که با درمان دارویی برطرف شد. در یک مورد اختلال خفیف شاخه حسی عصب رادیال روی داد که پس از مدتی برطرف شد و در هیچ مورد ضایعه تاندونی وجود نداشت. میانگین انحراف به طرف کف دست 6.6±5.4 و انحراف اولنار 4.5±12.5 بود.   در 4 مورد درد هنگام فعالیت های شدید، 2 مورد محدودیت حرکت خفیف و یک مورد محدودیت حرکت شدید وجود داشت. نتیجه گیری: در مقایسه با سایر مطالعات نتایج این مطالعه در بسیاری از موارد خیلی بهتر است و توصیه می شود که در درمان شکستگی های ناپایدار انتهای تحتانی رادیوس و بخصوص در صورت توسعه به داخل مفصل رادیوکارپال از این روش درمانی استفاده شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 932

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 176 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

نشریه: 

Eklem Hastalik Cerrahisi

اطلاعات دوره: 
  • سال: 

    2019
  • دوره: 

    30
  • شماره: 

    3
  • صفحات: 

    224-232
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    21
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 21

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1401
  • دوره: 

    20
  • شماره: 

    3 (مسلسل 78)
  • صفحات: 

    99-104
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    110
  • دانلود: 

    22
چکیده: 

مقدمه: شکستگی دیستال رادیوس (زند زبرین) بسیار شایع است. این شکستگی می تواند در همه گروه های سنی رخ دهد. روش های مختلفی برای درمان این نوع شکستگی ها وجود دارد. بررسی نتایج درمان شکستگی دیستال رادیوس با کاربرد فیکساتور خارجی به همراه پین گذاری زیرپوستی (bridging external fixator + (percutaneous pinning هدف ما در این مطالعه است. مواد و روش ها: این مطالعه مقطعی بین سال های 1397 تا 1400، در مرکز آموزشی درمانی بیمارستان کاشانی در شهر اصفهان، بر روی 72 بیمار انجام شد. شکستگی بیماران از نوع فرناندز 3، 4 و 5 بود و تحت درمان فیکساتور خارجی و پین گذاری برای شکستگی دیستال رادیوس قرار گرفته بودند. بیماران در فواصل 3 و 6 ماه پس از عمل، تحت معاینه مجدد قرار گرفتند. یافته ها: 72 بیمار در این مطالعه بررسی شدند. میانگین سنی 2/44 سال بود. 55 درصد از بیماران مرد و بقیه زن بودند. شایع ترین علت ایجاد شکستگی، تصادفات وسایل نقلیه بود. 4 مورد بدجوش خوردگی (malunion)، 4 مورد آسیب عصب رادیال سطحی، 2 مورد شل شدگی فیکساتور خارجی و 6 مورد عفونت سطحی در نتایج مطالعه یافت شد. نتیجه گیری: کاربرد فیکساتور خارجی یک روش درمانی مناسب برای درمان شکستگی های دیستال رادیوس، همراه با عوارض کم و سطح رضایت بالای بیمار است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 110

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 22 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 2
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button